info@innofj.comContact Engineering

Medical Contact Fiber Optic Temperature Measurement Device

An application-specific optical temperature measurement system for technically reviewed medical-contact and research measurement projects.

MEDICAL-CONTACT OPTICAL TEMPERATURE MEASUREMENT SYSTEM

Support a reviewed contact-temperature application with a passive optical sensing path and compatible acquisition instrument.

This option is intended for projects where support a reviewed contact-temperature application with a passive optical sensing path and compatible acquisition instrument.

A specialized measurement system for reviewed research or medical-contact applications, not a general-purpose transmitter or a medical certification claim.

  • Medical device research
  • Confirm sensor placement, materials, probe routing and final use with the application team before configuration.

Product Overview

Medical Contact Fiber Optic Temperature Measurement Device is designed for a defined role in a fiber optic temperature measurement project. An application-specific optical temperature measurement system for technically reviewed medical-contact and research measurement projects.

The final configuration should be selected from the measurement target, installation conditions and the components required around it. It should not be treated as a substitute for the other compatible parts of the optical measurement path.

Medical Contact Fiber Optic Temperature Measurement Device Selection Context

The equipment and temperature points determine whether this product is appropriate. A project review should establish the practical function it will perform before the configuration is finalized.

  • Measurement protocol
  • Contact location and materials

Configuring Medical Contact Fiber Optic Temperature Measurement Device

The selection process should connect the product to its installation route, compatible hardware and the way temperature information will be used.

  • Probe construction
  • Instrument and data requirements

Technical Specifications

Select the final configuration around the equipment design and required measurement points.

Temperature range20ºC~+50ºC(Customizable for higher temperature range) Resolution: 0.01ºC Response time ≤ 1 second Fiber diameter: 2.5mm Customizable Fiber optic temperature sensing probe diameter: 1.5mm Customizable Temperature measurement accuracy: ±0.3℃ (Can be customized for higher accuracy)
Number of channels1-64(Number of channels can be customized) Response time ≤ 100ms Lengths: 5M(Customizable length) Fiber Type: Quartz fiber optic Communication Method: RS485/Modbus-RTU Fiber optic connectorsn: ST Power Dissipation: ≤6W Working Voltage : AC/DC220V Customizable High voltage resistance: 100KV

Typical Project Uses

Selection should start with the actual application and the role this product plays in the complete optical measurement path.

Medical device research

Review this product’s role, installation method and related components against the actual application.

Contact temperature studies

Review this product’s role, installation method and related components against the actual application.

RF-adjacent laboratory work

Review this product’s role, installation method and related components against the actual application.

Specialized test equipment

Review this product’s role, installation method and related components against the actual application.

Frequently Asked Questions

What is the role of this medical-contact optical temperature measurement system?

It is used to address a specific fiber optic temperature measurement requirement. The final configuration should be checked against the application, connected probes and required outputs.

Does it include every component needed for measurement?

The final arrangement depends on the product role. Compatible probes, optical connections, power, enclosure integration and data interfaces should be confirmed for the project.

What information is needed for a configuration review?

Share the measurement target, installation environment, required number of points and any display, alarm or communication requirements. Measurement protocol should also be confirmed.

Related Components and Systems

These products serve different roles in the same optical temperature-measurement path.

Plan the Right Product Configuration

Tell us how this medical contact fiber optic temperature measurement device will be used. INNO can review the measurement point, installation route, channel requirements and system interface against the selected product.

  • Measurement target: Medical device research
  • Installation method: Confirm sensor placement, materials, probe routing and final use with the application team before configuration.
  • Product selection: Measurement protocol
  • System requirement: Instrument and data requirements

Include the operating temperature range, number of measurement points and required communication or alarm outputs where applicable.

Tell Us About Your Application
Contact Engineering

Tell us about your application, or contact us directly by Email: info@innofj.com