info@innofj.comContact Engineering

MRI & RF Fiber Optic Temperature Probe

Compact point temperature sensing for reviewed MRI, RF, NMR and medical research environments.

STRONG-FIELD TEMPERATURE PROBE

Use a Non-Conductive Optical Measurement Path in Strong Fields

This compact fluorescence probe is intended for application-specific measurement projects where metallic or electrically conductive sensor leads may be unsuitable around MRI, RF or NMR equipment.

The probe is not a medical device certification and does not operate alone. The full measurement setup, materials, placement and compatible instrument location must be application-specific for the specific equipment and procedure.

  • Strong-field application review
  • 1.5 mm sensing tip
  • ±0.3 °C accuracy
  • 5 m fiber length

Product Overview

The MRI and RF fiber optic temperature probe is a passive, non-conductive fluorescence probe for specialized projects around MRI, RF, NMR and related strong-field equipment. The standard configuration supports a 1.5 mm sensing tip, 5 m optical fiber, a 20 °C to 50 °C range and ±0.3 °C accuracy.

Application conditions in these environments vary substantially. The probe should therefore be evaluated as part of the complete measurement setup, including its position, materials, fiber route and the compatible signal-processing instrument.

Strong-Field Measurement Setup Review

The suitability of a temperature probe depends on the complete installation, not only on the sensing tip.

  • Define the exact point to be measured.
  • Review placement relative to the field and test arrangement.
  • Confirm the selected instrument and fiber route for the project.

Defining Material and Instrument Position

The passive probe and the host instrument have different installation roles. Keep the instrument position and interface requirements explicit during planning.

  • Use the standard configuration as a reference starting point.
  • Confirm the required range and fiber length.
  • Do not treat this page as a medical certification statement.

Passive Point Sensing With a Compatible Instrument

The fluorescent sensing tip measures one selected point. A compatible instrument supplies the optical excitation, processes the returned signal and provides the temperature output. See the standard fluorescence probe for the full measurement principle.

Compact Strong-Field Probe Setup

The measurement setup is defined by the probe position, permitted materials, optical route and compatible instrument placement around the actual equipment.

Compact sensing tip

The listed 1.5 mm tip supports selected temperature points with limited available space.

Non-conductive optical path

Temperature information returns to the instrument optically rather than through a conductive sensor lead.

Separated instrument location

The compatible signal-processing instrument is positioned according to the complete test or research setup.

When to Choose the MRI & RF Probe

Choose this compact probe for research and equipment testing projects that require a passive optical sensing point around strong electromagnetic fields.

  • MRI equipment development and testing
  • RF and NMR research environments
  • Medical-device thermal research
  • Compact non-conductive sensing points
  • Projects with a reviewed instrument location

Key Probe Features

Strong-Field Application

The passive optical path suits application-specific MRI, RF and NMR measurement projects.

Compact Sensing Tip

A 1.5 mm sensing-tip diameter supports limited measurement spaces.

High-Resolution Configuration

The standard configuration supports ±0.3 °C accuracy and 0.01 °C resolution.

Non-Conductive Path

Temperature information returns optically to the instrument.

Fast Response

The collected probe configuration lists response within 100 ms.

Procedure-Specific Review

Materials, positioning and equipment compatibility must be assessed for each project.

Technical Specifications

Choose the final probe construction and compatible instrument for the application.

Sensing methodFluorescence decay point measurement
temperature range+20 °C to +50 °C configurable
accuracy±0.3 °C configurable
resolution0.01 °C with compatible instrument
response time≤100 ms
sensing-tip diameter1.5 mm configurable
fiber diameter2.5 mm configurable
fiber length5 m configurable
optical materialQuartz
System requirementCompatible fluorescence instrument required

Parameters to Confirm Before Ordering

Equipment and procedureAvailable spaceFiber routeTemperature requirement

Review the Complete Measurement Setup

The sensing tip must contact the actual temperature point while the optical route is protected through the equipment.

Target Point

Optical Route

Compatible Instrument

  • Define the exact measurement point and acceptable probe materials.
  • Confirm probe geometry, fiber route and compatible equipment access.
  • Locate the signal-processing instrument according to the test setup.
  • Validate the complete setup for the intended research or equipment procedure.

Typical Applications

Open the related industry or solution page for application-specific measurement and installation guidance.

Compatible Products for This Application

These products have different roles in the measurement path and are selected according to the installation.

Frequently Asked Questions

Is this probe certified for every MRI procedure?

No. Compatibility and use must be evaluated for the specific equipment, procedure, materials and installation.

Is the probe itself a complete thermometer?

No. It is a passive sensing probe and requires a compatible fluorescence instrument.

What temperature range is listed?

The standard configuration supports +20 °C to +50 °C, with project configuration subject to confirmation.

Can the fiber length be changed?

The standard configuration supports 5 m and indicates configurable length. Final availability should be confirmed for the setup.

Does one probe measure multiple points?

No. One fluorescent sensing tip measures one point.

What project information should be provided?

Share the equipment type, procedure, temperature range, accuracy need, available space, fiber route and instrument location.

Review an MRI or RF Probe Configuration

Describe the equipment, measurement point, temperature range, available space, material constraints, fiber route and compatible instrument location.

  • Measurement location
  • Required temperature range
  • Fiber route and length
Tell Us About Your Measurement Point

Need Help Selecting the Correct Probe Construction?

Share the measurement point, environment and installation constraints with INNO.

Request a Configuration
Contact Engineering